LAB-001 / Energy and pumping

Pump Energy Analyzer

Pump Performance, Energy & Diagnostics Simulator — explore the operating point, energy consumption and diagnostic signals of a centrifugal pump.

LAB-001 V2 / Centrifugal pump simulator

From the operating point to the decision.

● Valid domain · hydraulic and energy model
Interactive exploration

Operating Point

Operating flow rate Simulated
80 L/s
Total head Simulated
30 m
H–Q curvesSimulated model · not certified
Pump and system curves and operating pointIntersection: 80 L/s and 30 m. Values available using the control below.001732336450966612883159H (m)Q (L/s)OP
━ Pump┄ System● Operating point

Pump H: 30.16 m · System H: 29.85 m

The intersection balances the head supplied by the pump and required by the system. Changing K moves the point; the effect on power also depends on efficiency.

Simulator equations and assumptions

Hₚ = H₀n² − aQ²
Hₛ = H static + KQ²
Q* = √[(H₀n² − H static)/(a + K)]

ηₚ = ηmax − c[Q/(nQ BEP) − 1]²
Pₕ = ρgQH / 1000
Pₑ = Pₕ / (ηₚηₘηᵥ)

E = Pₑ × hours
Cost = E × tariff
r = P observed − P expected
Deviation = 100r/P expected

Q in m³/s; H in m; a and K in s²/m⁵; ρ in kg/m³; g = 9.81 m/s²; power in kW. n is a dimensionless ratio. Energy in kWh. Annual hours at constant load; tariff excludes taxes, fixed charges and tiers.

Public model / assumptions and limits

A laboratory for testing explanations

These curves are synthetic and educational, not certified manufacturer curves. The model assumes water or an incompressible fluid of constant density, steady state, fixed geometry and a single pump. It does not cover NPSH, cavitation, viscosity, transients, parallel pumps or mechanical limits.

Affinity laws approximate Q ∝ n and H ∝ n² at homologous points. P ∝ n³ also requires similar efficiency; it does not apply automatically to a system with static head. The parabolic efficiency curve is an adjustable assumption, valid here only for 0.4 ≤ Q/(nQ BEP) ≤ 1.4 and 0.5 ≤ n ≤ 1.2. These educational limits do not authorise operation of real equipment.

Technical reference: KSB · Pump affinity laws. Installation validation requires manufacturer curves and limits and independent measurements.

From publication to laboratory

The related article is not available yet.

In Fault Scenarios, compare A, B and C; in Physical Diagnostics, scenario C adds 3.2 kW to the indication without changing actual power or annual cost. A single signal does not demonstrate waste. Scenario A changes hydraulic service and B changes system losses.

The related article is not available yet.

LAB-001 / original calculator retained

Check field measurements

Calculator independent of the simulator: enter simultaneous measurements to estimate apparent overall efficiency.

Inputs

Results

Calculated hydraulic power
23.54 kW
Apparent overall efficiency
73.3 %

Converted flow rate · 0.0800 m³/s

73.3%

Measurement calculator equations

Pₕ = ρ × g × Q × H

ρ in kg/m³, g = 9.81 m/s², Q in m³/s and H in m. Divide the result in W by 1 000 to obtain kW.

η = (Pₕ / Pₑ) × 100

Compare hydraulic and electrical powers in kW. Divide flow rate by 1 000 for L/s or by 3 600 for m³/h.

Assumes steady state, constant fluid density and simultaneous measurements. Use total head and active electrical power measured at the system boundary. The model does not separate pump, motor and drive losses.