Pump Energy Analyzer
Pump Performance, Energy & Diagnostics Simulator — explore the operating point, energy consumption and diagnostic signals of a centrifugal pump.
Operating Point
- Operating flow rate Simulated
- 80 L/s
- Total head Simulated
- 30 m
Pump H: 30.16 m · System H: 29.85 m
The intersection balances the head supplied by the pump and required by the system. Changing K moves the point; the effect on power also depends on efficiency.
Simulator equations and assumptions
Hₚ = H₀n² − aQ²Hₛ = H static + KQ²Q* = √[(H₀n² − H static)/(a + K)]
ηₚ = ηmax − c[Q/(nQ BEP) − 1]²Pₕ = ρgQH / 1000Pₑ = Pₕ / (ηₚηₘηᵥ)
E = Pₑ × hoursCost = E × tariffr = P observed − P expectedDeviation = 100r/P expected
Q in m³/s; H in m; a and K in s²/m⁵; ρ in kg/m³; g = 9.81 m/s²; power in kW. n is a dimensionless ratio. Energy in kWh. Annual hours at constant load; tariff excludes taxes, fixed charges and tiers.
A laboratory for testing explanations
These curves are synthetic and educational, not certified manufacturer curves. The model assumes water or an incompressible fluid of constant density, steady state, fixed geometry and a single pump. It does not cover NPSH, cavitation, viscosity, transients, parallel pumps or mechanical limits.
Affinity laws approximate Q ∝ n and H ∝ n² at homologous points. P ∝ n³ also requires similar efficiency; it does not apply automatically to a system with static head. The parabolic efficiency curve is an adjustable assumption, valid here only for 0.4 ≤ Q/(nQ BEP) ≤ 1.4 and 0.5 ≤ n ≤ 1.2. These educational limits do not authorise operation of real equipment.
Technical reference: KSB · Pump affinity laws. Installation validation requires manufacturer curves and limits and independent measurements.
The related article is not available yet.
In Fault Scenarios, compare A, B and C; in Physical Diagnostics, scenario C adds 3.2 kW to the indication without changing actual power or annual cost. A single signal does not demonstrate waste. Scenario A changes hydraulic service and B changes system losses.
The related article is not available yet.
Check field measurements
Calculator independent of the simulator: enter simultaneous measurements to estimate apparent overall efficiency.
Results
- Calculated hydraulic power
- 23.54 kW
- Apparent overall efficiency
- 73.3 %
Converted flow rate · 0.0800 m³/s
Measurement calculator equations
Pₕ = ρ × g × Q × Hρ in kg/m³, g = 9.81 m/s², Q in m³/s and H in m. Divide the result in W by 1 000 to obtain kW.
η = (Pₕ / Pₑ) × 100Compare hydraulic and electrical powers in kW. Divide flow rate by 1 000 for L/s or by 3 600 for m³/h.
Assumes steady state, constant fluid density and simultaneous measurements. Use total head and active electrical power measured at the system boundary. The model does not separate pump, motor and drive losses.